- M3HiuDocumentRepository::persistFromDataFetch no longer includes the
per-call request_id in the document dedup hash. request_id is unique
every time data_fetch runs, so it was causing a brand-new duplicate
row to be inserted on every re-fetch of the exact same ABDM document.
Now dedup key is transaction_id + consent_ref + care_context_reference
+ bundle_id, which stays stable across repeated fetches -> re-fetches
UPDATE the existing row instead of duplicating it.
- Added Patient::abdm_content_fetch_only() + route
billing/patient/abdm_content_fetch_only/(id): a lightweight action for
when consent is already GRANTED/COMPLETED. It calls data_fetch directly
using the saved consent reference, skipping consent_request + reconcile
polling entirely, avoiding unnecessary bridge calls/noise.
- Patient_Profile_Opd_V.php: added a 'Fetch Records' button that only
appears once consent phase is GRANTED or COMPLETED, wired to the new
endpoint; on success it refreshes the document list in place. The
original 'Fetch ABDM Records' button still owns the full consent
request -> reconcile -> fetch flow and already stops/re-enables
correctly on DENIED/FAILED (verified, no change needed there).
- One-time cleanup: deduped existing abdm_hiu_documents rows in dev DB
(13 -> 3) and recomputed doc_hash with the new stable key.
Adds a 'Verify SSL Certificate' switch on Admin -> ABDM Gateway page,
persisted as hospital_setting.ABDM_BRIDGE_SSL_VERIFY (default ON/secure).
Wired into M3HiuGatewayClient, EAtriaBridgeConnector, and the settings
page's own Test Connection check. Per-machine ABDM_BRIDGE_SSL_VERIFY env
var still overrides this DB setting for deployments needing a quick
local-only workaround. Verification stays on by default everywhere;
disabling it is an explicit, visible opt-in with an on-page warning.
- add facility QR support and OPD queue bridge fixes
- support care-context push warnings for lab, radiology, IPD and remaining HI types
- improve ABHA patient matching and diagnosis autocomplete performance
- clean up webcam streams on page navigation
Serialize the full repaired body instead of only the temporary wrapper contents so DOMDocument recovery does not drop later discharge sections before mPDF rendering.